Selecting the right Active Fire Protection (AFP) systems for industrial warehouses is crucial for protecting employees, assets, and the surrounding community from the devastating effects of fires. AFP systems are designed to detect and suppress fires or provide a means of egress during an emergency. They encompass systems inclusive of fire sprinklers, fire alarms, and the smoke control systems. Detection systems play a critical role in active fire protection by identifying and alerting occupants to the
presence of a fire, allowing them to take appropriate action to extinguish or evacuate the area. Fire detection systems are an extremely essential fire safety tool for any organization because they were created to quickly detect flames as they spread. Losses that are legitimately incurred can be significantly decreased by utilizing fire detection systems. It is possible to reduce downtime for commercial operations. While the fire is still small, fire control operations can commence. Detection systems are designed to detect smoke, heat, or flames and can be either automatic or manual. They provide early warning, trigger AFP systems, locate the fire, identify the type of fire, and monitor the environment. These roles all work together to help prevent fires from spreading, minimize damage, and protect the safety of occupants and assets.


Full Text:

PDF

References


Allen, T. & Molina, R., 2006. Warehouse sprinkler design configurations not covered by NFPA 13. Fire Protection Engineering, Volume 16, p. 29.

Alpert, R. L., 1971. Calculation of Response Time of ceiling mounted fire detectors. Fire Technology, 8(3), pp. 181-195.

Anon., 2003. International Fire Code (IFC).. s.l.:s.n.

Anon., n.d. Warehouse Commodity Classification from Fundamental principles.Part II: Flame Heights and Flame Spread, s.l.: s.n.

Bureau of Indian Standards, 1991. IS 3594: 1991 Code of practice for fire safety and industrial buildings. s.l.:s.n.

Dasgupta, R., Solanki, S. K. & Paul, V., 2021. Post-pandemic impact on planning of district. Int. J. Built Environment and Asset Management, pp. 162-182.

Dinaburg, J. & Gottuk, D., 2012. Fire Detection in Warehouse Facilities, s.l.: SpringerBriefs in Fire.

Gallagher, R., 2011. WAREHOUSE CHALLENGE-Three forward-looking approaches to fixed fire protection to extinguish fires in large warehouses without fire service intervention. NFPA Journal-National Fire Protection Association, 105(4), p. 42.

Golinveaux, J. & Hankins, J., 2006. Meeting the Challenges of an Ever-Changing Storage Industry How to select the right sprinklers for storage/distribution and retail" big box" facilities. Fire Protection Engineering, Volume 29, p. 32.

Gottuk, D. T., 2008. Video Image Detection Systems Installation Performance Criteria Research Project, s.l.: Fire Protection Research Foundation.

Gupta, N., Solanki, S. K. & Mittal, M., 2022. Effectiveness of Amendment of GCC on Claims by CPWD in 2019. International Journal for Research in Applied Science & Engineering Technology (IJRASET), pp. 3130-3146.

Kasana, V., Paul, V. & Solanki, S. K., 2022. Framework for Rehabilitation of Buildings to Improve Health, Hygiene, and Comfort of Occupants. INTERNATIONAL JOURNAL OF TOWN PLANNING AND MANAGEMENT, pp. 9, 38-46.

Kumar, K. & Paul, V. K., 2022. A Critical Review of Risk Factors and Reliability Assessment Issues of Fire and Life Safety in Buildings. NICMAR JOURNAL OF CONSTRUCTION MANAGEMENT, XXXVII(III), pp. 23-33.

Kumar, K. & Paul, V. K., 2022. Risk and Reliability Assessment of Smoke Control Systems in the Buildings. International Journal for Research in Applied Science & Engineering Technology (IJRASET), 10(X), pp. 576-581.

Kumar, K. & Paul, V. K., 2023. Significance of Fire Protection System Reliability for Structure Fire Safety. STRUCTURAL ENGINEERING DIGEST, Issue October-December, pp. 42-25.

Meibach Research, 2010. Miebach India Warehousing, s.l.: s.n.

Paul, V. K., Basu, C., Rastogi, A. & Kumar, K., 2022. Status of Fire Safety in Healthcare Facilities in India. International Journal of Architecture and Infrastructure Planning; https://architecture.journalspub.info/index.php?journal=JAIP&page=index, 8(1), pp. 1-11.

Robert Accosta, J. & Drew Martin, P., 2017. Smoke Detector spacing for high ceiling spaces, s.l.: NFPA,Research Foundation.

Solanki, S. K. & Paul, V. K., 2022. Comparison between service life prediction methods for building rehabilitation: application on a case study. Journal of Building Pathology and Rehabilitation, pp. 1-13.

Solanki, S. K., Rastogi, A. & Khursheed, S., 2022. Techno-Managerial Approach to Building Rehabilitation. 1 ed. s.l.:Copal Publishing.

The National Fire Protection Association, 2003. Standard for the fire protection of storage. NFPA 230.

Zalosh & Robert, G., 2003. Industrial Fire Protection Engineering, s.l.: s.n.


Refbacks

  • There are currently no refbacks.